AOR SDU-5000 Manual de instrucciones Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 39
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
29
To activate the Waterfall Function, press the [FUNC] key and press the [ . ] (decimal) key
on the numeric keys.
The lower half of the LCD will be used to display waterfalls.
The Waterfall Function will not be affected by changing of the Operation mode,
Calculation mode, Marker function, Resolution, Center frequency, Frequency span, Start
frequency, End (stop) frequency, and so forth.
The strength of signals are visible by color in 16 steps.
Blue Light Blue Green Yellow Red
( weak ----------------- strong)
To stop
the Waterfall Function, press the [FUNC] key and press the [ . ] (decimal) key.
To quit
the Waterfall Function, press the [CLR] key on the numeric keys.
6-10 Display Setting
Press the [FUNC] key and press the [5] key will toggle between the receiver information
display on and off. This will give you a wider screen view of the LCD.
[Receiver information ON] [Receiver information OFF]
6-11 Beep On / Off
Press the [FUNC] key and press the [6] key will toggle between the beep sound on and
off.
6-12 Resetting the SDU5600
If you wish the SDU5600 to return to the factory default settings, perform the following
steps:
1. Turn the SDU5600 power off.
2. Press and hold the [ 3 ] key and [ 6 ] key simultaneously while turning the power
on.
3. After the LCD displays the “EEROM initialized message, then release the [ 3 ]
key and the [ 6 ] key.
7 Getting Started