AOR SDU-5000 Manual de instrucciones Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 39
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
20
Enter the Start Frequency and the End (Stop) Frequency using the Special Function
Keys located on the lower side of the LCD display and the numeric keys followed by
the [ENT] key ([KHz] key or [MHz] key.)
[Memo: Displayed frequency range:
Spectrum Analyzer Mode --- CF (Center Frequency) +/- (Frequency span/2)
Step Resolution Mode --- CF (Center Frequency) +/- (Display step x 160)
The Frequency span on the above example: 25 KHz x 320 steps = 8 MHz)
6-6-3 Channel Scope Mode
On the above screen, the following information is displayed.
Start frequency: 118.0 MHz
Step frequency: 25 KHz
End (Stop) frequency: 122.0 MHz
Frequency span: 4 MHz
Marker frequency: 121.8 MHz
Receive marker frequency:119.7 MHz
Unlike the Spectrum Analyzer mode or Step Resolution mode, the CF (Center
Frequency) setting is not available in the Channel Scope Mode.
Start Frequency (Ch. START
)
Press the [Ch. START] key using the left Special Function Keys. The icon indicating
the current start frequency will be reversed prompting the entry of new start frequency.
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 38 39

Comentarios a estos manuales

Sin comentarios