24
The first one has 4 KHz of RBW and the second has 128 KHz of RBW settings.
Greater detail is obtained by narrow RBW, however, you can get faster refresh rates
by using wide RBW.
Therefore, a proper RBW should be selected according to your application.
[Note: When monitoring a signal that has a wide bandwidth such as wideband FM or
high speed digital communications by a narrow RBW filter, the signal strength
readout may become different. This occurs due to its narrow filter.
As most of signal’s energy is filtered out by the RBW filter, the output
from the filter may become reduced before filtering.]
6-7 Marker Function
Selection of Marker / Peak / Continuous Peak is available with your SDU5600.
To select the marker function, press the [FUNC] key and press the [MK.F] key on the
numeric keypad.
Each selection is defied by a respective key on the Special Function Keys.