AR5000 Frequency stability
Measured for a ‘typical’ stock set.
Measured at 20 MHz from cold. Room temperature approx. 25 degree Celsius.
Time Elapsed Frequency change from start
0 0 Hz
1 minute 3 Hz
2 minutes 4 Hz
3 minutes 6 Hz
4 minutes 8 Hz
5 minutes 9 Hz
10 minutes 16 Hz
20 minutes 25 Hz
30 minutes 30 Hz
40 minute 33 Hz
50 minutes 35 Hz
1 hour 36 Hz
2 hours 37 Hz
i.e.
Under 2ppm from cold in 1
st
hour.
0.05ppm in subsequent hour.
AR5000 Local Oscillator Phase Noise Measurements
The following measurements are from a 'typical' AR5000 receiver. Figures supplied by AOR
Japan 19 December 1997.
VCO
dBC/Hz
25KHz Offset
50KHz Offset
VCO1 10KHz 622.4MHz 109 112
15KH 637.4MHz 110 112
29KHz 651.4MHz 109 111
VC02 30MHz 652.4MHz 103 108
103MHz 725.4MHz 103 108
174MHz 796.4MHz 104 108
675MHz 1297.4MHz 98 104
825MHz 1447.4MHz 98 106
974MHz 1596.4MHz 100 107
VC03 175MHz 979.4MHz 102 107
258MHz 889.4MHz 102 107